Updates settings for a global table.
See also: AWS API Documentation
See ‘aws help’ for descriptions of global parameters.
update-global-table-settings
--global-table-name <value>
[--global-table-billing-mode <value>]
[--global-table-provisioned-write-capacity-units <value>]
[--global-table-provisioned-write-capacity-auto-scaling-settings-update <value>]
[--global-table-global-secondary-index-settings-update <value>]
[--replica-settings-update <value>]
[--cli-input-json | --cli-input-yaml]
[--generate-cli-skeleton <value>]
--global-table-name
(string)
The name of the global table
--global-table-billing-mode
(string)
The billing mode of the global table. If
GlobalTableBillingMode
is not specified, the global table defaults toPROVISIONED
capacity billing mode.
PROVISIONED
- We recommend usingPROVISIONED
for predictable workloads.PROVISIONED
sets the billing mode to Provisioned Mode .
PAY_PER_REQUEST
- We recommend usingPAY_PER_REQUEST
for unpredictable workloads.PAY_PER_REQUEST
sets the billing mode to On-Demand Mode .Possible values:
PROVISIONED
PAY_PER_REQUEST
--global-table-provisioned-write-capacity-units
(long)
The maximum number of writes consumed per second before DynamoDB returns a
ThrottlingException.
--global-table-provisioned-write-capacity-auto-scaling-settings-update
(structure)
Auto scaling settings for managing provisioned write capacity for the global table.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring auto scaling policy.
ScalingPolicyUpdate -> (structure)
The scaling policy to apply for scaling target global table or global secondary index capacity units.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
Shorthand Syntax:
MinimumUnits=long,MaximumUnits=long,AutoScalingDisabled=boolean,AutoScalingRoleArn=string,ScalingPolicyUpdate={PolicyName=string,TargetTrackingScalingPolicyConfiguration={DisableScaleIn=boolean,ScaleInCooldown=integer,ScaleOutCooldown=integer,TargetValue=double}}
JSON Syntax:
{
"MinimumUnits": long,
"MaximumUnits": long,
"AutoScalingDisabled": true|false,
"AutoScalingRoleArn": "string",
"ScalingPolicyUpdate": {
"PolicyName": "string",
"TargetTrackingScalingPolicyConfiguration": {
"DisableScaleIn": true|false,
"ScaleInCooldown": integer,
"ScaleOutCooldown": integer,
"TargetValue": double
}
}
}
--global-table-global-secondary-index-settings-update
(list)
Represents the settings of a global secondary index for a global table that will be modified.
(structure)
Represents the settings of a global secondary index for a global table that will be modified.
IndexName -> (string)
The name of the global secondary index. The name must be unique among all other indexes on this table.
ProvisionedWriteCapacityUnits -> (long)
The maximum number of writes consumed per second before DynamoDB returns a
ThrottlingException.
ProvisionedWriteCapacityAutoScalingSettingsUpdate -> (structure)
Auto scaling settings for managing a global secondary index’s write capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring auto scaling policy.
ScalingPolicyUpdate -> (structure)
The scaling policy to apply for scaling target global table or global secondary index capacity units.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
JSON Syntax:
[
{
"IndexName": "string",
"ProvisionedWriteCapacityUnits": long,
"ProvisionedWriteCapacityAutoScalingSettingsUpdate": {
"MinimumUnits": long,
"MaximumUnits": long,
"AutoScalingDisabled": true|false,
"AutoScalingRoleArn": "string",
"ScalingPolicyUpdate": {
"PolicyName": "string",
"TargetTrackingScalingPolicyConfiguration": {
"DisableScaleIn": true|false,
"ScaleInCooldown": integer,
"ScaleOutCooldown": integer,
"TargetValue": double
}
}
}
}
...
]
--replica-settings-update
(list)
Represents the settings for a global table in a Region that will be modified.
(structure)
Represents the settings for a global table in a Region that will be modified.
RegionName -> (string)
The Region of the replica to be added.
ReplicaProvisionedReadCapacityUnits -> (long)
The maximum number of strongly consistent reads consumed per second before DynamoDB returns a
ThrottlingException
. For more information, see Specifying Read and Write Requirements in the Amazon DynamoDB Developer Guide .ReplicaProvisionedReadCapacityAutoScalingSettingsUpdate -> (structure)
Auto scaling settings for managing a global table replica’s read capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring auto scaling policy.
ScalingPolicyUpdate -> (structure)
The scaling policy to apply for scaling target global table or global secondary index capacity units.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ReplicaGlobalSecondaryIndexSettingsUpdate -> (list)
Represents the settings of a global secondary index for a global table that will be modified.
(structure)
Represents the settings of a global secondary index for a global table that will be modified.
IndexName -> (string)
The name of the global secondary index. The name must be unique among all other indexes on this table.
ProvisionedReadCapacityUnits -> (long)
The maximum number of strongly consistent reads consumed per second before DynamoDB returns a
ThrottlingException
.ProvisionedReadCapacityAutoScalingSettingsUpdate -> (structure)
Auto scaling settings for managing a global secondary index replica’s read capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring auto scaling policy.
ScalingPolicyUpdate -> (structure)
The scaling policy to apply for scaling target global table or global secondary index capacity units.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ReplicaTableClass -> (string)
Replica-specific table class. If not specified, uses the source table’s table class.
JSON Syntax:
[
{
"RegionName": "string",
"ReplicaProvisionedReadCapacityUnits": long,
"ReplicaProvisionedReadCapacityAutoScalingSettingsUpdate": {
"MinimumUnits": long,
"MaximumUnits": long,
"AutoScalingDisabled": true|false,
"AutoScalingRoleArn": "string",
"ScalingPolicyUpdate": {
"PolicyName": "string",
"TargetTrackingScalingPolicyConfiguration": {
"DisableScaleIn": true|false,
"ScaleInCooldown": integer,
"ScaleOutCooldown": integer,
"TargetValue": double
}
}
},
"ReplicaGlobalSecondaryIndexSettingsUpdate": [
{
"IndexName": "string",
"ProvisionedReadCapacityUnits": long,
"ProvisionedReadCapacityAutoScalingSettingsUpdate": {
"MinimumUnits": long,
"MaximumUnits": long,
"AutoScalingDisabled": true|false,
"AutoScalingRoleArn": "string",
"ScalingPolicyUpdate": {
"PolicyName": "string",
"TargetTrackingScalingPolicyConfiguration": {
"DisableScaleIn": true|false,
"ScaleInCooldown": integer,
"ScaleOutCooldown": integer,
"TargetValue": double
}
}
}
}
...
],
"ReplicaTableClass": "STANDARD"|"STANDARD_INFREQUENT_ACCESS"
}
...
]
--cli-input-json
| --cli-input-yaml
(string)
Reads arguments from the JSON string provided. The JSON string follows the format provided by --generate-cli-skeleton
. If other arguments are provided on the command line, those values will override the JSON-provided values. It is not possible to pass arbitrary binary values using a JSON-provided value as the string will be taken literally. This may not be specified along with --cli-input-yaml
.
--generate-cli-skeleton
(string)
Prints a JSON skeleton to standard output without sending an API request. If provided with no value or the value input
, prints a sample input JSON that can be used as an argument for --cli-input-json
. Similarly, if provided yaml-input
it will print a sample input YAML that can be used with --cli-input-yaml
. If provided with the value output
, it validates the command inputs and returns a sample output JSON for that command. The generated JSON skeleton is not stable between versions of the AWS CLI and there are no backwards compatibility guarantees in the JSON skeleton generated.
See ‘aws help’ for descriptions of global parameters.
Note
To use the following examples, you must have the AWS CLI installed and configured. See the Getting started guide in the AWS CLI User Guide for more information.
Unless otherwise stated, all examples have unix-like quotation rules. These examples will need to be adapted to your terminal’s quoting rules. See Using quotation marks with strings in the AWS CLI User Guide .
To update provisioned write capacity settings on a DynamoDB global table
The following update-global-table-settings
example sets the provisioned write capacity of the MusicCollection
global table to 15.
aws dynamodb update-global-table-settings \
--global-table-name MusicCollection \
--global-table-provisioned-write-capacity-units 15
Output:
{
"GlobalTableName": "MusicCollection",
"ReplicaSettings": [
{
"RegionName": "eu-west-1",
"ReplicaStatus": "UPDATING",
"ReplicaProvisionedReadCapacityUnits": 10,
"ReplicaProvisionedReadCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
},
"ReplicaProvisionedWriteCapacityUnits": 10,
"ReplicaProvisionedWriteCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
}
},
{
"RegionName": "us-east-1",
"ReplicaStatus": "UPDATING",
"ReplicaProvisionedReadCapacityUnits": 10,
"ReplicaProvisionedReadCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
},
"ReplicaProvisionedWriteCapacityUnits": 10,
"ReplicaProvisionedWriteCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
}
},
{
"RegionName": "us-east-2",
"ReplicaStatus": "UPDATING",
"ReplicaProvisionedReadCapacityUnits": 10,
"ReplicaProvisionedReadCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
},
"ReplicaProvisionedWriteCapacityUnits": 10,
"ReplicaProvisionedWriteCapacityAutoScalingSettings": {
"AutoScalingDisabled": true
}
}
]
}
For more information, see DynamoDB Global Tables in the Amazon DynamoDB Developer Guide.
GlobalTableName -> (string)
The name of the global table.
ReplicaSettings -> (list)
The Region-specific settings for the global table.
(structure)
Represents the properties of a replica.
RegionName -> (string)
The Region name of the replica.
ReplicaStatus -> (string)
The current state of the Region:
CREATING
- The Region is being created.
UPDATING
- The Region is being updated.
DELETING
- The Region is being deleted.
ACTIVE
- The Region is ready for use.ReplicaBillingModeSummary -> (structure)
The read/write capacity mode of the replica.
BillingMode -> (string)
Controls how you are charged for read and write throughput and how you manage capacity. This setting can be changed later.
PROVISIONED
- Sets the read/write capacity mode toPROVISIONED
. We recommend usingPROVISIONED
for predictable workloads.
PAY_PER_REQUEST
- Sets the read/write capacity mode toPAY_PER_REQUEST
. We recommend usingPAY_PER_REQUEST
for unpredictable workloads.LastUpdateToPayPerRequestDateTime -> (timestamp)
Represents the time when
PAY_PER_REQUEST
was last set as the read/write capacity mode.ReplicaProvisionedReadCapacityUnits -> (long)
The maximum number of strongly consistent reads consumed per second before DynamoDB returns a
ThrottlingException
. For more information, see Specifying Read and Write Requirements in the Amazon DynamoDB Developer Guide .ReplicaProvisionedReadCapacityAutoScalingSettings -> (structure)
Auto scaling settings for a global table replica’s read capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring the auto scaling policy.
ScalingPolicies -> (list)
Information about the scaling policies.
(structure)
Represents the properties of the scaling policy.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ReplicaProvisionedWriteCapacityUnits -> (long)
The maximum number of writes consumed per second before DynamoDB returns a
ThrottlingException
. For more information, see Specifying Read and Write Requirements in the Amazon DynamoDB Developer Guide .ReplicaProvisionedWriteCapacityAutoScalingSettings -> (structure)
Auto scaling settings for a global table replica’s write capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring the auto scaling policy.
ScalingPolicies -> (list)
Information about the scaling policies.
(structure)
Represents the properties of the scaling policy.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ReplicaGlobalSecondaryIndexSettings -> (list)
Replica global secondary index settings for the global table.
(structure)
Represents the properties of a global secondary index.
IndexName -> (string)
The name of the global secondary index. The name must be unique among all other indexes on this table.
IndexStatus -> (string)
The current status of the global secondary index:
CREATING
- The global secondary index is being created.
UPDATING
- The global secondary index is being updated.
DELETING
- The global secondary index is being deleted.
ACTIVE
- The global secondary index is ready for use.ProvisionedReadCapacityUnits -> (long)
The maximum number of strongly consistent reads consumed per second before DynamoDB returns a
ThrottlingException
.ProvisionedReadCapacityAutoScalingSettings -> (structure)
Auto scaling settings for a global secondary index replica’s read capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring the auto scaling policy.
ScalingPolicies -> (list)
Information about the scaling policies.
(structure)
Represents the properties of the scaling policy.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ProvisionedWriteCapacityUnits -> (long)
The maximum number of writes consumed per second before DynamoDB returns a
ThrottlingException
.ProvisionedWriteCapacityAutoScalingSettings -> (structure)
Auto scaling settings for a global secondary index replica’s write capacity units.
MinimumUnits -> (long)
The minimum capacity units that a global table or global secondary index should be scaled down to.
MaximumUnits -> (long)
The maximum capacity units that a global table or global secondary index should be scaled up to.
AutoScalingDisabled -> (boolean)
Disabled auto scaling for this global table or global secondary index.
AutoScalingRoleArn -> (string)
Role ARN used for configuring the auto scaling policy.
ScalingPolicies -> (list)
Information about the scaling policies.
(structure)
Represents the properties of the scaling policy.
PolicyName -> (string)
The name of the scaling policy.
TargetTrackingScalingPolicyConfiguration -> (structure)
Represents a target tracking scaling policy configuration.
DisableScaleIn -> (boolean)
Indicates whether scale in by the target tracking policy is disabled. If the value is true, scale in is disabled and the target tracking policy won’t remove capacity from the scalable resource. Otherwise, scale in is enabled and the target tracking policy can remove capacity from the scalable resource. The default value is false.
ScaleInCooldown -> (integer)
The amount of time, in seconds, after a scale in activity completes before another scale in activity can start. The cooldown period is used to block subsequent scale in requests until it has expired. You should scale in conservatively to protect your application’s availability. However, if another alarm triggers a scale out policy during the cooldown period after a scale-in, application auto scaling scales out your scalable target immediately.
ScaleOutCooldown -> (integer)
The amount of time, in seconds, after a scale out activity completes before another scale out activity can start. While the cooldown period is in effect, the capacity that has been added by the previous scale out event that initiated the cooldown is calculated as part of the desired capacity for the next scale out. You should continuously (but not excessively) scale out.
TargetValue -> (double)
The target value for the metric. The range is 8.515920e-109 to 1.174271e+108 (Base 10) or 2e-360 to 2e360 (Base 2).
ReplicaTableClassSummary -> (structure)
Contains details of the table class.
TableClass -> (string)
The table class of the specified table. Valid values are
STANDARD
andSTANDARD_INFREQUENT_ACCESS
.LastUpdateDateTime -> (timestamp)
The date and time at which the table class was last updated.