Modifies the parameters of a DB cluster parameter group to the default value. To reset specific parameters submit a list of the following: ParameterName
and ApplyMethod
. To reset the entire DB cluster parameter group, specify the DBClusterParameterGroupName
and ResetAllParameters
parameters.
When resetting the entire group, dynamic parameters are updated immediately and static parameters are set to pending-reboot
to take effect on the next DB instance restart or RebootDBInstance request. You must call RebootDBInstance for every DB instance in your DB cluster that you want the updated static parameter to apply to.
See also: AWS API Documentation
See ‘aws help’ for descriptions of global parameters.
reset-db-cluster-parameter-group
--db-cluster-parameter-group-name <value>
[--reset-all-parameters | --no-reset-all-parameters]
[--parameters <value>]
[--cli-input-json | --cli-input-yaml]
[--generate-cli-skeleton <value>]
--db-cluster-parameter-group-name
(string)
The name of the DB cluster parameter group to reset.
--reset-all-parameters
| --no-reset-all-parameters
(boolean)
A value that is set to
true
to reset all parameters in the DB cluster parameter group to their default values, andfalse
otherwise. You can’t use this parameter if there is a list of parameter names specified for theParameters
parameter.
--parameters
(list)
A list of parameter names in the DB cluster parameter group to reset to the default values. You can’t use this parameter if the
ResetAllParameters
parameter is set totrue
.(structure)
Specifies a parameter.
ParameterName -> (string)
Specifies the name of the parameter.
ParameterValue -> (string)
Specifies the value of the parameter.
Description -> (string)
Provides a description of the parameter.
Source -> (string)
Indicates the source of the parameter value.
ApplyType -> (string)
Specifies the engine specific parameters type.
DataType -> (string)
Specifies the valid data type for the parameter.
AllowedValues -> (string)
Specifies the valid range of values for the parameter.
IsModifiable -> (boolean)
Indicates whether (
true
) or not (false
) the parameter can be modified. Some parameters have security or operational implications that prevent them from being changed.MinimumEngineVersion -> (string)
The earliest engine version to which the parameter can apply.
ApplyMethod -> (string)
Indicates when to apply parameter updates.
Shorthand Syntax:
ParameterName=string,ParameterValue=string,Description=string,Source=string,ApplyType=string,DataType=string,AllowedValues=string,IsModifiable=boolean,MinimumEngineVersion=string,ApplyMethod=string ...
JSON Syntax:
[
{
"ParameterName": "string",
"ParameterValue": "string",
"Description": "string",
"Source": "string",
"ApplyType": "string",
"DataType": "string",
"AllowedValues": "string",
"IsModifiable": true|false,
"MinimumEngineVersion": "string",
"ApplyMethod": "immediate"|"pending-reboot"
}
...
]
--cli-input-json
| --cli-input-yaml
(string)
Reads arguments from the JSON string provided. The JSON string follows the format provided by --generate-cli-skeleton
. If other arguments are provided on the command line, those values will override the JSON-provided values. It is not possible to pass arbitrary binary values using a JSON-provided value as the string will be taken literally. This may not be specified along with --cli-input-yaml
.
--generate-cli-skeleton
(string)
Prints a JSON skeleton to standard output without sending an API request. If provided with no value or the value input
, prints a sample input JSON that can be used as an argument for --cli-input-json
. Similarly, if provided yaml-input
it will print a sample input YAML that can be used with --cli-input-yaml
. If provided with the value output
, it validates the command inputs and returns a sample output JSON for that command. The generated JSON skeleton is not stable between versions of the AWS CLI and there are no backwards compatibility guarantees in the JSON skeleton generated.
See ‘aws help’ for descriptions of global parameters.
DBClusterParameterGroupName -> (string)
The name of the DB cluster parameter group.
Constraints:
Must be 1 to 255 letters or numbers.
First character must be a letter
Cannot end with a hyphen or contain two consecutive hyphens
Note
This value is stored as a lowercase string.