[ aws . iotsitewise ]

update-gateway-capability-configuration

Description

Updates a gateway capability configuration or defines a new capability configuration. Each gateway capability defines data sources for a gateway. A capability configuration can contain multiple data source configurations. If you define OPC-UA sources for a gateway in the IoT SiteWise console, all of your OPC-UA sources are stored in one capability configuration. To list all capability configurations for a gateway, use DescribeGateway .

See also: AWS API Documentation

Synopsis

  update-gateway-capability-configuration
--gateway-id <value>
--capability-namespace <value>
--capability-configuration <value>
[--cli-input-json | --cli-input-yaml]
[--generate-cli-skeleton <value>]
[--debug]
[--endpoint-url <value>]
[--no-verify-ssl]
[--no-paginate]
[--output <value>]
[--query <value>]
[--profile <value>]
[--region <value>]
[--version <value>]
[--color <value>]
[--no-sign-request]
[--ca-bundle <value>]
[--cli-read-timeout <value>]
[--cli-connect-timeout <value>]
[--cli-binary-format <value>]
[--no-cli-pager]
[--cli-auto-prompt]
[--no-cli-auto-prompt]

Options

--gateway-id (string)

The ID of the gateway to be updated.

--capability-namespace (string)

The namespace of the gateway capability configuration to be updated. For example, if you configure OPC-UA sources from the IoT SiteWise console, your OPC-UA capability configuration has the namespace iotsitewise:opcuacollector:version , where version is a number such as 1 .

--capability-configuration (string)

The JSON document that defines the configuration for the gateway capability. For more information, see Configuring data sources (CLI) in the IoT SiteWise User Guide .

--cli-input-json | --cli-input-yaml (string) Reads arguments from the JSON string provided. The JSON string follows the format provided by --generate-cli-skeleton. If other arguments are provided on the command line, those values will override the JSON-provided values. It is not possible to pass arbitrary binary values using a JSON-provided value as the string will be taken literally. This may not be specified along with --cli-input-yaml.

--generate-cli-skeleton (string) Prints a JSON skeleton to standard output without sending an API request. If provided with no value or the value input, prints a sample input JSON that can be used as an argument for --cli-input-json. Similarly, if provided yaml-input it will print a sample input YAML that can be used with --cli-input-yaml. If provided with the value output, it validates the command inputs and returns a sample output JSON for that command. The generated JSON skeleton is not stable between versions of the AWS CLI and there are no backwards compatibility guarantees in the JSON skeleton generated.

Global Options

--debug (boolean)

Turn on debug logging.

--endpoint-url (string)

Override command’s default URL with the given URL.

--no-verify-ssl (boolean)

By default, the AWS CLI uses SSL when communicating with AWS services. For each SSL connection, the AWS CLI will verify SSL certificates. This option overrides the default behavior of verifying SSL certificates.

--no-paginate (boolean)

Disable automatic pagination. If automatic pagination is disabled, the AWS CLI will only make one call, for the first page of results.

--output (string)

The formatting style for command output.

  • json
  • text
  • table
  • yaml
  • yaml-stream

--query (string)

A JMESPath query to use in filtering the response data.

--profile (string)

Use a specific profile from your credential file.

--region (string)

The region to use. Overrides config/env settings.

--version (string)

Display the version of this tool.

--color (string)

Turn on/off color output.

  • on
  • off
  • auto

--no-sign-request (boolean)

Do not sign requests. Credentials will not be loaded if this argument is provided.

--ca-bundle (string)

The CA certificate bundle to use when verifying SSL certificates. Overrides config/env settings.

--cli-read-timeout (int)

The maximum socket read time in seconds. If the value is set to 0, the socket read will be blocking and not timeout. The default value is 60 seconds.

--cli-connect-timeout (int)

The maximum socket connect time in seconds. If the value is set to 0, the socket connect will be blocking and not timeout. The default value is 60 seconds.

--cli-binary-format (string)

The formatting style to be used for binary blobs. The default format is base64. The base64 format expects binary blobs to be provided as a base64 encoded string. The raw-in-base64-out format preserves compatibility with AWS CLI V1 behavior and binary values must be passed literally. When providing contents from a file that map to a binary blob fileb:// will always be treated as binary and use the file contents directly regardless of the cli-binary-format setting. When using file:// the file contents will need to properly formatted for the configured cli-binary-format.

  • base64
  • raw-in-base64-out

--no-cli-pager (boolean)

Disable cli pager for output.

--cli-auto-prompt (boolean)

Automatically prompt for CLI input parameters.

--no-cli-auto-prompt (boolean)

Disable automatically prompt for CLI input parameters.

Examples

Note

To use the following examples, you must have the AWS CLI installed and configured. See the Getting started guide in the AWS CLI User Guide for more information.

Unless otherwise stated, all examples have unix-like quotation rules. These examples will need to be adapted to your terminal’s quoting rules. See Using quotation marks with strings in the AWS CLI User Guide .

To update a gateway capability

The following update-gateway-capability-configuration example configures an OPC-UA source with the following properties:

  • Trusts any certificate.
  • Uses the Basic256 algorithm to secure messages.
  • Uses the SignAndEncrypt mode to secure connections.
  • Uses authentication credentials stored in an AWS Secrets Manager secret.
aws iotsitewise update-gateway-capability-configuration \
    --gateway-id a1b2c3d4-5678-90ab-cdef-1a1a1EXAMPLE \
    --capability-namespace "iotsitewise:opcuacollector:1" \
    --capability-configuration file://opc-ua-capability-configuration.json

Contents of opc-ua-capability-configuration.json:

{
    "sources": [
        {
            "name": "Wind Farm #1",
            "endpoint": {
                "certificateTrust": {
                    "type": "TrustAny"
                },
                "endpointUri": "opc.tcp://203.0.113.0:49320",
                "securityPolicy": "BASIC256",
                "messageSecurityMode": "SIGN_AND_ENCRYPT",
                "identityProvider": {
                    "type": "Username",
                    "usernameSecretArn": "arn:aws:secretsmanager:us-west-2:123456789012:secret:greengrass-windfarm1-auth-1ABCDE"
                },
                "nodeFilterRules": []
            },
            "measurementDataStreamPrefix": ""
        }
    ]
}

Output:

{
    "capabilityNamespace": "iotsitewise:opcuacollector:1",
    "capabilitySyncStatus": "OUT_OF_SYNC"
}

For more information, see Configuring data sources in the AWS IoT SiteWise User Guide.

Output

capabilityNamespace -> (string)

The namespace of the gateway capability.

capabilitySyncStatus -> (string)

The synchronization status of the capability configuration. The sync status can be one of the following:

  • IN_SYNC – The gateway is running the capability configuration.
  • NOT_APPLICABLE – Synchronization is not required for this capability configuration. This is most common when integrating partner data sources, because the data integration is handled externally by the partner.
  • OUT_OF_SYNC – The gateway hasn’t received the capability configuration.
  • SYNC_FAILED – The gateway rejected the capability configuration.
  • UNKNOWN – The synchronization status is currently unknown due to an undetermined or temporary error.

After you update a capability configuration, its sync status is OUT_OF_SYNC until the gateway receives and applies or rejects the updated configuration.